Fire alarm systems
Conventional Fire Alarms
C-TEC’s MFP Range of conventional fire alarm control panels fills the
gap between low cost, low specification fire alarm control panels and high
price, high specification equipment.
Expandable from 4 to 28 zones in four zone steps, the
MFP's balance of features and competitive pricing makes it
ideal for a variety of applications, ranging from new
installations to upgrades and extensions of new systems.
Easy to follow wiring instructions are printed adjacent to
the terminals of all variants and a lift-off lid guarantees an
easy first fix and straightforward maintenance.
Fully compliant with BS 5839 Part 4 and the head removal
requirements of BS 5839 Part 1, a variety of ‘add on’ boards
are also available, converting the MFP into one of the most
sophisticated fire panels available.
MFP Range Features
- Fully compliant with BS5839 Part 4.
- Microprocessor based design.
- Robust metal lid and metal back box.
- Attractive easy-to-clean polycarbonate front label.
- Four sounder circuits and head out (detector
removed) fault indication provided as standard.
- Expandable from 4 to 28 zones in 4 zone steps.
- Heavy-duty base connections.
- Ultra-bright, long-life LED indicators.
- Built-in 24V power supply and battery charger.
- End of line units included (one per zone).
- Compatibility with virtually all known conventional
smoke and heat detector ranges.
- True three wire operation of sounder and detector
circuits (Ov is common) for considerable cost
savings on installation.
- Separate indication of open circuit fault, short
circuit fault, head out fault, sounder fault and
battery/power supply fault.
- Non-latching 'class change' sounder input, latching
fire and non-latching fault outputs (available via
optional MFPX expansion loom).
- Fault buzzer mute facility.
- Space available for the rated capacity of VRLA
batteries.
- Short circuit = fire facility (pre-1980 BS, no resistors
in call points), selectable on a zone by zone basis for
retro-installations.
- Non-latching zones facility for cross connection to
other panels.
- True battery monitoring circuit.
- Wide range of engineer facilities including one man
detector test, sounder walk test, sounder isolate,
sounder delay and auxiliary isolate.
- Easy to follow installation instructions and log book.
- Up to eight two-wire repeaters with full external
control (except isolate) per system (requires one
FF596T Repeater Transmitter PCB fitted at the main
panel).
- Multilingual variants available (subject to quantities).